Search

Engineering thiol-ene click chemistry for the preparation of a chiral stationary phase based on a [4+6]-type homochiral porous organic cage for enantiomeric separation in normal-phase and reversed-phase high performance liquid chromatography

메타 데이터

바이오화학분류
    • 바이오플라스틱
      1. 플라스틱
    • 바이오정밀화학
      1. 용매
      2. 화학제품
논문

Engineering thiol-ene click chemistry for the preparation of a chiral stationary phase based on a [4+6]-type homochiral porous organic cage for enantiomeric separation in normal-phase and reversed-phase high performance liquid chromatography

학술지

Journal of chromatography A

저자명

Liang, Rui-Xue; Zhang, You-Ping; Zhang, Jun-Hui; Gong, Ya-Nan; Huang, Bin; Wang, Bang-Jin; Xie, Sheng-Ming; Yuan, Li-Ming

초록

In this study, a new chiral stationary phase (CSP) was fabricated by covalent bonding of a [4+6]-type homochiral porous organic cage (POC) CC19-R onto thiolated silica via a thiol-ene click reaction. The CC19-R was synthesized via Schiff-base reaction between 2-hydroxybenzene-1,3,5-tricarbaldehyde and (1R, 2R)-(-)-1,2-diaminocyclohexane. The enantioseparation capability of the resulting CC19-R-based CSP was systematically evaluated upon separating various chiral compounds or chiral pharmaceuticals in normal phase HPLC (NP-HPLC) and reversed phase HPLC (RP-HPLC), including alcohols, organic acids, ketones, diols, esters, and amines. Fifteen racemates were enantioseparated in NP-HPLC and 11 racemates in RP-HPLC. Some racemates have been well separated, such as 4-chlorobenzhydrol, cetirizine (in the form of dihydrochloride), 1,2-diphenyl-1,2-ethanediol, and 3-(benzyloxy)propane-1,2-diol whose resolution values reached 3.66, 4.23, 6.50, and 3.50, respectively. When compared with a previously reported chiral POC-based column (NC1-R column), eight racemates were not separated on the NC1-R column in NP-HPLC and five racemates were not separated in RP-HPLC, but were well resolved on this column, revealing that the enantioselectivity and separable range of chiral POCs-type columns could be significantly widened using this fabricated CC19-R column. Moreover, the resolution performance of the CC19-R column was also compared with commercial Chiralpak AD-H [CSP: Amylose tris(3,5-dimethylphenylcarbamate)] and Chiralcel OD-H [CSP: Cellulose tris(3,5-dimethylphenylcarbamate)] columns. The column also can separate some racemates that could not be separated or not well be separated by the two commercial columns, showing its good complementarity to the two commercial columns on chiral separation. In addition, the column also had good stability and reproducibility with the relative standard deviation (n = 5) of the retention time and resolution lower than 1.0% and 1.8%, respectively, after it had undergone multiple injections (100, 200, 300, and 400 times). This work indicated that the features of good resolution ability and simple synthesis methods using with this POC-based CSP provided chiral POCs with potential application prospects in HPLC racemic separation.

발행연도

2023

발행기관

Elsevier

ISSN

0021-9673

ISSN

1873-3778

1711

페이지

pp.464444

0건의 논문이 있습니다.

0건의 특허가 있습니다.

0건의 무역이 있습니다.

1건의 후보군 물질이 있습니다.

1 2023-12-11

논문; 2023-11-22

Export

About

Search

Trend