Search

Highly sensitive determination of L-glutamic acid in pig serum with an enzyme-free molecularly imprinted polymer on a carbon-nanotube modified electrode

메타 데이터

바이오화학분류
    • 바이오플라스틱
      1. 기타
    • 바이오정밀화학
      1. 기타
    • 의료용 화학소재
      1. 식품첨가제
논문

Highly sensitive determination of L-glutamic acid in pig serum with an enzyme-free molecularly imprinted polymer on a carbon-nanotube modified electrode

학술지

Analytical methods : advancing methods and applications

저자명

Yu, Xin-Yao; He, Jun-Yi; Tang, Fei; Yu, Peng; Wu, Ling; Xiao, Zhong-Liang; Sun, Li-Xian; Cao, Zhong; Yu, Donghong

초록

<P>Through electrochemical polymerization using l-glutamic acid (l-Glu) as a template and 4,6-diaminoresorcinol as a functional monomer, an enzyme-free molecularly imprinted polymer (MIP) based l-Glu sensor with multi-walled carbon nanotubes (MWCNTs) decorated on a glassy carbon electrode (GCE), namely G-MIP/MWCNTs/GCE, was developed in this work. The reaction conditions were optimized as follows: electrochemical polymerization of 23 cycles, pH of 3.0, molar ratio of template/monomer of 1 : 4, volume ratio of elution reagents of acetonitrile/formic acid of 1 : 1, and elution time of 2 min. The prepared materials and molecularly imprinted polymer were characterized by using scanning electron microscopy (SEM) and transmission electron microscopy (TEM) as well as electrochemical methods. The electrochemical properties of different electrodes were investigated <I>via</I> differential pulse voltammetry (DPV), showing that the electrode of G-MIP/MWCNTs/GCE exhibited excellent catalytic oxidation activity towards l-Glu. A good linear relationship between peak-currents and l-Glu concentrations in a range from 1.00 &times; 10<SUP>&#x2212;8</SUP> to 1.00 &times; 10<SUP>&#x2212;5</SUP> mol L<SUP>&#x2212;1</SUP> was observed, with a detection limit of 5.13 &times; 10<SUP>&#x2212;9</SUP> mol L<SUP>&#x2212;1</SUP> (S/N = 3). The imprinted sensor possesses excellent selectivity, high sensitivity, and good stability, which have been successfully applied for the detection of l-Glu in pig serum samples with a recovery rate of 97.4-105.5%, being comparable to commercial high-performance liquid chromatography, demonstrating a simple, rapid, and accurate way for the determination of l-Glu in the fields of animal nutrition and biomedical engineering.</P>

발행연도

2023

발행기관

The Royal Society of Chemistry

ISSN

1759-9660

ISSN

1759-9679

15

42

페이지

pp.5589-5597

0건의 논문이 있습니다.

0건의 특허가 있습니다.

0건의 무역이 있습니다.

1건의 후보군 물질이 있습니다.

1 2023-12-11

논문; 2023-11-02

Export

About

Search

Trend