Search

4-(Triethoxysilyl)butanoic acid as a self-assembled monolayer for surface modification of titanium dioxide

메타 데이터

바이오화학분류
    • 의료용 화학소재
      1. 치료제
논문

4-(Triethoxysilyl)butanoic acid as a self-assembled monolayer for surface modification of titanium dioxide

학술지

The Analyst : An International Journal of Analytical and Bioanalytical Science

저자명

Lai, Yu-Hsing; Lee, Yan-Chang; Li, Hsun-Yuan; Hsieh, Wen-Hsin

초록

<P>In this study, the carboxy silane 4-(triethoxysilyl)butanoic acid (TESBA) was used to modify titanium dioxide (TiO<SUB>2</SUB>) to create a self-assembled monolayer (SAM) and then directionally immobilize a capture antibody using protein A. We selected the amino silane (3-aminopropyl)triethoxysilane (APTES) to perform a comparative analysis with TESBA, and employed glutaraldehyde (GA) as the control. The modification and detection effects and the limit of detection (LOD) were evaluated by detecting human immunoglobulin G (IgG). The average normalized sensitivity of the dual-grating coupler waveguide biosensor was 49.63 ± 0.27 RIU<SUP>&#x2212;1</SUP> and the optimum resolution was 1.30 &times; 10<SUP>&#x2212;6</SUP> RIU. When the SAM was prepared using TESBA and APTES followed by GA, the LOD was 4.59 &times; 10<SUP>&#x2212;7</SUP> g mL<SUP>&#x2212;1</SUP> and 5.29 &times; 10<SUP>&#x2212;7</SUP> g mL<SUP>&#x2212;1</SUP>, respectively. We analyzed the modification and detection effects by the <I>t</I>-test and concluded that the differences in the modification effects using TESBA and APTES followed by GA were significant and the differences in the detection effects using TESBA and APTES followed by GA were insignificant. The use of TESBA as the SAM led to the modification effect being superior to that obtained using APTES followed by GA. The detection effect using TESBA was as outstanding as that using APTES followed by GA. Our findings demonstrate the feasibility and effectiveness of using TESBA as the SAM to carboxylate the surface of TiO<SUB>2</SUB>, thereby enabling immobilization of biomolecules for human IgG detection.</P><P>Graphic Abstract</P><P>4-(Triethoxysilyl)butanoic acid was used to modify TiO<SUB>2</SUB> to create a self-assembled monolayer and then directionally immobilize a capture antibody using protein A.<BR/><IMG SRC='http://pubs.rsc.org/services/images/RSCpubs.ePlatform.Service.FreeContent.ImageService.svc/ImageService/image/GA?id=d3an01795h'/><BR/></P>

발행연도

2024

발행기관

The Royal Society of Chemistry

ISSN

0003-2654

ISSN

1364-5528

149

4

페이지

pp.1202-1211

0건의 논문이 있습니다.

0건의 특허가 있습니다.

0건의 무역이 있습니다.

1건의 후보군 물질이 있습니다.

1 2023-12-11

논문; 2024-02-12

Export

About

Search

Trend