Search

Ultrasound-Enhanced Attenuated Total Reflection Mid-infrared Spectroscopy In-Line Probe: Acquisition of Cell Spectra in a Bioreactor

메타 데이터

바이오화학분류
    • 바이오플라스틱
      1. 기타
    • 바이오정밀화학
      1. 기타
논문

Ultrasound-Enhanced Attenuated Total Reflection Mid-infrared Spectroscopy In-Line Probe: Acquisition of Cell Spectra in a Bioreactor

학술지

Analytical chemistry

저자명

Koch, Cosima; Brandstetter, Markus; Wechselberger, Patrick; Lorantfy, Bettina; Plata, Maria Reyes; Radel, Stefan; Herwig, Christoph; Lendl, Bernhard

초록

<P/><P>This article presents a novel method for selective acquisition of Fourier transform infrared (FT-IR) spectra of microorganisms in-line during fermentation, using <I>Saccharomyces cerevisiae</I> as an example. The position of the cells relative to the sensitive region of the attenuated total reflection (ATR) FT-IR probe was controlled by combing a commercially available ATR in-line probe with contact-free, gentle particle manipulation by ultrasonic standing waves. A prototype probe was successfully constructed, assembled, and tested in-line during fed-batch fermentations of <I>S. cerevisiae</I>. Control over the position of the cells was achieved by tuning the ultrasound frequency: 2.41 MHz was used for acquisition of spectra of the cells (pushing frequency <I>f</I><SUB>p</SUB>) and 1.87 MHz, for retracting the cells from the ATR element, therefore allowing spectra of the medium to be acquired. Accumulation of storage carbohydrates (trehalose and glycogen) inside the cells was induced by a lack of a nitrogen source in the feed medium. These changes in biochemical composition were visible in the spectra of the cells recorded in-line during the application of <I>f</I><SUB>p</SUB> and could be verified by reference spectra of dried cell samples recorded off-line with a FT-IR microscope. Comparison of the cell spectra with spectra of trehalose, glycogen, glucose, and mannan, i.e., the major carbohydrates present in <I>S. cerevisiae</I>, and principal components analysis revealed that the changes observed in the cell spectra correlated well with the bands specific for trehalose and glycogen. This proves the applicability and capability of ultrasound-enhanced in-line ATR mid-IR spectroscopy as a real-time PAT method for the in situ monitoring of cellular biochemistry during fermentation.</P>

발행연도

2015

발행기관

American Chemical Society

라이선스

cc-by

ISSN

0003-2700

ISSN

1520-6882

87

4

페이지

pp.2314-2320

0건의 논문이 있습니다.

0건의 특허가 있습니다.

0건의 무역이 있습니다.

1건의 후보군 물질이 있습니다.

1 2023-12-11

논문; 2015-01-26

Export

About

Search

Trend