Search

Comparison of coagulation and fibrinolysis in Irish Wolfhounds and age-matched control dogs using tissue plasminogen activator-augmented viscoelastic testing

메타 데이터

바이오화학분류
    • 의료용 화학소재
      1. 치료제
논문

Comparison of coagulation and fibrinolysis in Irish Wolfhounds and age-matched control dogs using tissue plasminogen activator-augmented viscoelastic testing

학술지

Journal of veterinary emergency and critical care

저자명

Davis, Samantha; Fletcher, Daniel J.; Newman, Ashley; Brooks, Marjory B.

초록

<P><B>Abstract</B><P>Objective<P>To determine if Irish Wolfhounds (IWs), like other sighthounds, are hyperfibrinolytic compared with nonsighthound dogs using 2 native and tissue plasminogen activator (tPA)&#x2010;enhanced viscoelastic assays, one that is whole blood&#x2010;based (viscoelastic coagulation monitor [VCM]) and the other that is plasma&#x2010;based thromboelastography (TEG).</P></P><P>Design<P>Cohort study.</P></P><P>Setting<P>University teaching hospital.</P></P><P>Animals<P>A convenience sample of 27 IWs recruited from the Irish Wolfhound Association of New England Specialty and the local community, and 27 healthy, age&#x2010;matched, large&#x2010;breed control dogs.</P></P><P>Interventions<P>None.</P></P><P>Measurements and Main Results<P>Blood samples including CBC, biochemistry, traditional coagulation, and viscoelastic testing were collected from IWs and control dogs. Twelve IWs had viscoelastic testing. IWs had lower fibrinogen concentrations (215.5 ± 57.8 vs 251.4 ± 64.5 mg/dL, <I>P</I> = 0.034) and formed weaker clots on both whole&#x2010;blood VCM and plasma TEG assays (maximum clot firmness [VCM&#x2010;MCF] = 39.4 [25.1-48.8] vs 48.5 [34.6-57.3], <I>P </I>= 0.0042; maximum amplitude [TEG&#x2010;MA] = 22.7 [14.7-33.6] vs 32.2 [26.9-42.0], <I>P</I> < 0.0001). IWs were hyperfibrinolytic compared with control dogs on VCM whole&#x2010;blood assays, with 25 U/mL tPA (lysis at 30 min [VCM&#x2010;LI30] = 68.1 [0-100] vs\ 99.9 [63.3-100], <I>P</I> = 0.0009; lysis at 45 min [VCM&#x2010;LI45] = 31.0 [0-100] vs 98.1 [38.4-100], <I>P</I> = 0.0002) but hypofibrinolytic compared with controls on TEG plasma assays with 50 U/mL tPA (lysis at 30 min [TEG&#x2010;LY30] = 45.7 [4.6-94.6] vs 93.7 [12.3-96.5], <I>P</I> = 0.0004; lysis at 60 min [TEG&#x2010;LY60] = 68.7 [29.7-96.8] vs 95.7 [34.4-97.6], <I>P</I> = 0.0003). Minimal fibrinolysis was measured on whole&#x2010;blood VCM or plasma TEG assays without the addition of tPA, and there were no differences between the 2 groups.</P></P><P>Conclusions<P>Weaker clots were found in IWs than control dogs. With the addition of tPA, IWs had evidence of hyperfibrinolysis on whole&#x2010;blood VCM assays and hypofibrinolysis on plasma TEG assays compared with control dogs. Without the addition of tPA, however, both groups of dogs showed minimal fibrinolysis on viscoelastic testing.</P></P></P>

발행연도

2024

발행기관

Wiley (Blackwell Publishing)

ISSN

1479-3261

ISSN

1476-4431

34

3

페이지

pp.222-230

0건의 논문이 있습니다.

0건의 특허가 있습니다.

0건의 무역이 있습니다.

1건의 후보군 물질이 있습니다.

논문; 2024-05-01

Export

About

Search

Trend